Evaporative Cooling

Evaporative Cooler CFM Calculator — Swamp Cooler Sizing

Size a swamp cooler the way installers do: 2–3 CFM per square foot stepped by climate, verified against the 20–40 ACH band that makes evaporation work — then check the exhaust openings and duct trunk the machine depends on.

Swamp cooler sizing panel

Pick your climate — it sets the CFM per sq ft

Area × climate factor

Conditioned area1,600 sq ft
Climate factor2.5 CFM/sq ft
Air changes19 ACH @ 8 ft
Required cooler4,000 CFM
Buy this class4,500 CFM unit

Exhaust openings needed

4.0–8.0

sq ft of open windows (1–2 per 1,000 CFM)

Duct velocity check

1,273 FPM

⚠ 24" trunk outside 800–1,200 — resize

Checkpoint: Comfortable for most of the season; July monsoon weeks are the stress test.

Swamp coolers are one climate-driven branch of home airflow: the free online CFM calculator covers the plain ACH sizing this page’s air-change rule descends from, and the CFM calculator toolset lists every sibling tool, from attic fans to whole-house systems.

The rule that surprises everyone

Why swamp coolers move 5× the air of an AC

An evaporative cooler plays a completely different game from refrigerated air conditioning, and its sizing reflects it. An AC recirculates a sealed volume over a 55°F coil, dropping the same air 20 degrees pass after pass — a few air changes per hour does it. A swamp cooler’s supply air, by contrast, is only 10–20°F below the outdoors to begin with, and each cubic foot spends its cooling budget in a single pass before it must leave through your open windows. The fix is volume: 20–40 air changes per hour, the highest of any home equipment, which at typical ceiling heights folds back to the shop-floor shortcut of 2–3 CFM per square foot.

20–40 ACH

One-pass cooling

Every cubic foot the pad cools is used once and exhausted. Sizing has to guarantee enough one-pass capacity to replace the whole house's air 20–40 times an hour.

1–2 sq ft / 1,000 CFM

Humidity is the exhaust

The cooler adds moisture with every pass; without open windows the room saturates and evaporation stops. The cracked window is not a leak — it is the return-air system.

2.0–3.0 CFM/sq ft

Climate sets the factor

Dry air absorbs moisture greedily (2.0 CFM/sq ft is plenty). Humid air barely accepts more (3.0+ and marginal). The zone buttons in the panel encode exactly this.

💡 The two rules agree

Check the arithmetic once and you own it forever: 1,000 sq ft × 8 ft ceilings = 8,000 cu ft. A 2,500 CFM cooler changes that house 2,500 × 60 ÷ 8,000 ≈ 19 times an hour — squarely in the 20–40 ACH band, and exactly the 2.5 CFM/sq ft a typical inland climate calls for. One sizing decision, two languages, no conflict.

Swamp cooler size charts, by climate

The two lookups that cover almost every house. Read your square footage under your climate column, then buy the nearest cooler class above your number — never below:

Floor area → CFM by climate zone

House areaHot-dry @ 2.0Inland @ 2.5Humid @ 3.0Open windows
800 sq ft1,600 CFM2,000 CFM2,400 CFM2.0–4.0 sq ft
1,000 sq ft2,000 CFM2,500 CFM3,000 CFM2.5–5.0 sq ft
1,200 sq ft2,400 CFM3,000 CFM3,600 CFM3.0–6.0 sq ft
1,500 sq ft3,000 CFM3,750 CFM4,500 CFM3.8–7.5 sq ft
1,800 sq ft3,600 CFM4,500 CFM5,400 CFM4.5–9.0 sq ft
2,200 sq ft4,400 CFM5,500 CFM6,600 CFM5.5–11.0 sq ft
2,600 sq ft5,200 CFM6,500 CFM7,800 CFM6.5–13.0 sq ft

Common cooler classes → the houses they fit

Cooler classTypical styleCovers (inland)ACH @ 8 ft
1,600 CFMWindow / portable≈ 640 sq ft19 ACH
2,400 CFMWindow / portable≈ 960 sq ft19 ACH
3,200 CFMWhole-house down-draft≈ 1,280 sq ft19 ACH
4,500 CFMWhole-house down-draft≈ 1,800 sq ft19 ACH
5,200 CFMWhole-house down-draft≈ 2,080 sq ft19 ACH
6,500 CFMWhole-house down-draft≈ 2,600 sq ft19 ACH
8,000 CFMWhole-house down-draft≈ 3,200 sq ft19 ACH
Rooftop evaporative cooler on a home in a dry southwestern climateThe box on the roof is a sizing decisionPhoto: Unsplash

Window cooler vs whole-house: same math, different footprint

Both styles obey the same CFM-per-square-foot rule — the only input that changes is the area you feed the formula. What separates them is where the air enters and how the exhaust is managed:

Window & portable coolers

  • Sized on the single room: a 200 sq ft bedroom at 2.0–2.5 CFM/sq ft wants 400–500 CFM — the classic window class.
  • Exhaust is handled by cracking a window in the NEXT room, so air sweeps through the space instead of short-circuiting.
  • Perfect for dry-climate renters and bedrooms that an AC never reaches.

Whole-house down-draft & side-draft

  • Sized on the full conditioned footprint, then mounted on roof or gable to dump into a central plenum.
  • Best installed through an unused furnace return so the existing duct trunk distributes at 800–1,200 FPM.
  • Two or three leeward windows stay cracked all season — plan furniture around it.

⚠️ The short-circuit mistake

A cooler pointed straight at an open door — or a window cooler in a room whose window you crack open right beside it — lets the supply air walk directly to the exit without touching the room. Distance the exhaust from the inlet: window cooler in the hallway, cracked window in the far bedroom. The whole house is your duct system.

Outlet & duct requirements at a glance

Cooler sizeDuct area @ 1,000 FPMRound trunkWindows open
1,600 CFM1.6 sq ft17"1.6–3.2 sq ft
2,400 CFM2.4 sq ft21"2.4–4.8 sq ft
3,200 CFM3.2 sq ft24"3.2–6.4 sq ft
4,500 CFM4.5 sq ft29"4.5–9.0 sq ft
5,200 CFM5.2 sq ft31"5.2–10.4 sq ft

Climate correction: where swamp coolers earn their keep

Evaporative cooling converts heat into humidity, so the whole machine lives or dies on how much moisture the incoming air can still absorb — the wet-bulb depression. The three zones in the calculator compress into one honest map:

Hot-dry desert

2 CFM/sq ft

Phoenix · Las Vegas · Reno

+ Ideal territory — wet-bulb depression is huge, so evaporation pulls temperatures down 20–30°F.

− Water use runs all summer; keep pads clean or efficiency fades.

Typical inland

2.5 CFM/sq ft

Denver · Sacramento · Salt Lake City

+ Comfortable for most of the season; July monsoon weeks are the stress test.

− Size at 2.5 CFM/sq ft, not the desert minimum, to ride through humid spells.

Marginal / humid

3 CFM/sq ft

Dallas · Memphis · coastal Southeast

+ Works only with maximum airflow and big exhaust openings — and even then, expect lukewarm results in August.

− Beyond ~70°F dew point, evaporation stalls; refrigerated AC becomes the honest answer.

🛠 Scope note: if August humidity puts your region beyond the marginal zone, the machine that matches your climate is refrigerated AC — sized a completely different way at 400 CFM per ton. That arithmetic lives on the CFM per ton calculator, and for moving air without cooling at all, the whole-house fan calculator covers the evening-flush strategy.

Four swamp cooler beliefs, tested against the math

Swamp coolers collect folklore faster than any other HVAC equipment. Each card pairs a belief with the sizing physics that settles it:

The belief

“A swamp cooler is just cheap air conditioning.”

The physics

Different physics, different math. AC recirculates sealed air over a cold coil at ~1 CFM/sq ft; a swamp cooler makes one pass per cubic foot and needs 2–3 CFM/sq ft plus permanent exhaust. Size one like the other and it fails in exactly the way you'd predict.

The belief

“Bigger pads mean more cooling — just add media.”

The physics

Pad area beyond the design set adds water and pressure drop, not temperature reduction. Cooling is capped by wet-bulb depression; once the pad is saturated, more surface only raises blower load and water bills.

The belief

“Close the house up so the cool air doesn't escape.”

The physics

Sealed rooms kill evaporation: humidity saturates, the pad stops transferring, and the blower just recirculates muggy air. The 1–2 sq ft of open window per 1,000 CFM is mandatory exhaust — the machine's return duct, just made of summer breeze.

The belief

“Evaporative coolers barely use any water, so run two.”

The physics

A whole-house cooler evaporates 15–25 gallons on a hot dry day; running an oversized pair doubles that while overshooting the ACH band into wind-chill territory. Buy one correctly sized unit and the water bill thanks you.

Evaporative cooler FAQ

TopHow do I use an evaporative cooler CFM calculator?▼

Enter your floor area, ceiling height and climate zone, and the calculator applies the swamp-cooler sizing rule — 2 to 3 CFM per square foot depending on how dry your air is. A 1,600 sq ft single-story house in a hot-dry climate needs about 1,600 × 2.0 = 3,200 CFM; the same house in a more humid region wants 4,000–4,800. The calculator also converts the result into air changes per hour (the 20–40 ACH band evaporative coolers live in) and tells you how much open window area the system needs to push air through. That last number is the one swamp cooler owners most often miss.

How many CFM per square foot does a swamp cooler need?▼

The trade shortcut is 2–3 CFM per square foot, stepped by climate: 2.0 for hot-dry deserts, 2.5 for typical inland climates, and 3.0 or more where humidity creeps in. At typical 8 ft ceilings that works out to roughly 15–25 air changes per hour — and the wider published guidance for evaporative cooling stretches the band to 20–40 ACH because these machines move enormous volumes of air compared to any other home equipment. When a sizing chart says a 2,000 sq ft house needs a 4,000–5,000 CFM cooler, it is this same arithmetic. An evaporative cooler sizing guide built on CFM per square foot will always land you in the right cooler class.

Why do evaporative coolers need so many air changes?▼

Because they cool by trading sensible heat for humidity, and the trade only works while fresh air keeps arriving. A refrigerated AC recirculates a sealed volume through a cold coil and can drop the same air 20 degrees on every pass; an evaporative cooler's supply air is only 10–20 degrees below outdoor temperature to begin with, and each cubic foot gives up its cooling potential in a single visit before exiting out your open windows. The 20–40 ACH rule is what keeps the average room temperature between the supply temperature and the outdoor temperature. Throttle the airflow down and you don't save energy — you just let the house drift toward the swamp outside.

What size swamp cooler for a 1,500 sq ft house?▼

Multiply by the climate factor: 1,500 × 2.0 = 3,000 CFM in a dry climate (a 3,200 CFM class unit), 1,500 × 2.5 = 3,750 (the 4,500 class), and 1,500 × 3.0 = 4,500 at the humid margin. With 9 ft ceilings the room volumes grow, so lean to the upper choice. Practically, the common answer is a 4,200–5,200 CFM whole-house unit — which is why 4,500 and 5,200 CFM down-draft coolers dominate the rooftop landscape in the Mountain West. Undersizing is the single most common swamp cooler mistake: the machine runs constantly and the house never quite gets comfortable.

Do evaporative coolers work in humid climates?▼

Fading honesty, zone by zone. Evaporative cooling is governed by wet-bulb depression — the gap between the air's dry-bulb and wet-bulb temperatures. In Phoenix that gap is enormous and coolers shine; in Memphis in August the gap nearly closes and the pad adds humidity the air cannot absorb. Below roughly 50°F dew point, results are good; 50–60°F dew point is marginal and demands the full 3 CFM/sq ft plus wide-open exhaust; above that, a swamp cooler mostly makes the house muggy. Two-stage (indirect-direct) coolers extend the range by pre-cooling air without adding humidity, but they cost several times more.

How much window opening does a swamp cooler need?▼

Plan on 1–2 square feet of open window or vent area per 1,000 CFM of cooler — a 4,500 CFM whole-house unit wants 4.5–9 sq ft of escape routes, typically two or three windows cracked 6–10 inches. The openings do double duty: they let the heat-laden air leave and they cap the static pressure so the blower keeps delivering rated CFM. Close the house tight and the cooler suffocates — airflow collapses, humidity saturates the rooms, and the damp environment starts feeding odors and condensation on cool surfaces. Crack windows on the leeward side of the house and the air self-steers across the living space.

What duct size does an evaporative cooler need?▼

Low velocity, high volume: evaporative ducts move air at just 800–1,200 FPM, because the goal is quiet, gentle delivery rather than chip-transport or throw. A 4,500 CFM cooler at 1,000 FPM needs 4.5 sq ft of duct area — roughly a 29-inch round trunk, which is why whole-house coolers usually dump into a large ceiling diffuser or an unused furnace return plenum instead of long duct runs. Undersized ducts choke these blowers fast; the calculator's duct check flags any size that pushes past 1,200 FPM before you buy the collar.

Window unit or whole-house cooler — how does sizing differ?▼

The CFM-per-square-foot math is identical; what changes is the area you feed it. A window cooler is sized on the single room it serves — a 200 sq ft bedroom in a dry climate is 200 × 2 = 400 CFM, so the popular 500 CFM window class covers it with margin. Whole-house units are sized on the entire conditioned footprint and then mounted on roof or wall to dump into a central plenum. The mistake to avoid is double counting: a window cooler in the bedroom plus a whole-house unit both running just fight each other through the open windows you're paying to keep cracked.

How does swamp cooler ACH compare to air conditioning?▼

It's a different universe: an evaporative cooler targets 20–40 air changes per hour, while a refrigerated AC system typically conditions its ducted airflow at the equivalent of 5–8 room changes per hour and recirculates it. That is not AC being lazy — the AC re-cools the same air dozens of times, so its CFM per ton (around 400) is optimized for coil contact, not air replacement. The swamp cooler's air makes one pass and leaves. This is also why you never mix the logic: an evap cooler sized at AC's 1 CFM per sq ft would be half the airflow it needs, and an AC sized at 3 CFM per sq ft would be an arctic hurricane.

Can I seal the house and recirculate like an AC?▼

No — and understanding why teaches you the whole machine. An evaporative cooler continuously adds moisture to the supply air; without exhaust, indoor humidity climbs until the pads can no longer evaporate, cooling stops entirely, and you have built a humidifier. The open windows are not wasted energy, they are the exhaust system — the evaporative equivalent of the return duct an AC depends on. If your climate or your doors-and-windows lifestyle can't accommodate permanent openings, the machine that matches your life is refrigerated AC, not a swamp cooler.

Related Tools & Guides

🌀

CFM to FPM Calculator

Convert CFM to FPM and FPM to CFM for any round or rectangul...

🔄

CFM Conversion Calculator

Convert CFM to m³/h, CMH, CMM, L/s, LPM, m³/s and CFH instan...

🔥

CFM to BTU Calculator

Convert CFM to BTU and BTU to CFM with the 1.08 ΔT formula —...

⚙️

Fan Performance Calculator

Calculate fan CFM from RPM with the affinity laws — static p...

🍳

Range Hood CFM Calculator

Free range hood CFM calculator: size kitchen hoods by cookto...

☀️

Attic Fan CFM Calculator

Attic fan CFM calculator: size attic exhaust at 0.7–1.0 CFM ...

🔧

Air Compressor CFM Calculator

Air compressor CFM calculator: total your tools' CFM at 90 P...

🌡️

SCFM to CFM Calculator

SCFM to CFM calculator with pressure and temperature correct...

🌀

Blower CFM Calculator

Blower CFM calculator: size any blower from wheel diameter, ...

🌱

Grow Tent CFM Calculator

Grow tent CFM calculator: size 2×2 to 4×8 tents by air chang...

❄️

CFM per Ton Calculator

CFM per ton calculator: convert tons to CFM at 350, 400 or 4...

🪵

Dust Collector CFM Calculator

Dust collector CFM calculator: match machine CFM demands, ke...

🎨

Paint Booth CFM Calculator

Paint booth CFM calculator: size cross-draft and downdraft s...

🌫️

Air Purifier CFM Calculator

Air purifier CFM calculator: match CADR to room size with th...

🌬️

Air Handler CFM Calculator

Air handler CFM calculator: split supply vs return air, chec...

🏎️

Engine CFM Calculator

Engine CFM calculator: size carburetors from CID and RPM wit...

🌿

Greenhouse CFM Calculator

Greenhouse CFM calculator: summer cooling at one exchange pe...

🚿

Bathroom Exhaust Fan CFM Calculator

Bathroom exhaust fan CFM calculator: size by room volume at ...

🔁

Air Changes per Hour Calculator

Convert air changes per hour to CFM and back with the ACH fo...

📐

CFM to Square Feet Calculator

Turn CFM into square feet: coverage area from 700, 1500 or 3...

🏡

Whole House Fan CFM: Sizing Whole-House Fans, HRVs & ERVs

Size a whole-house fan at 2–3 CFM per sq ft or one air chang...

Square footage in, cooler class out

Pick your climate zone, feed the panel your floor area, and walk away with CFM, air changes, exhaust openings and the duct verdict.